歡迎來到匠仁醫(yī)療設(shè)備有限公司網(wǎng)站!

更多 > 新聞資訊
公司新聞
行業(yè)知識
檢測答疑
圖標(biāo) 首頁 >> 新聞資訊 > 公司新聞

公司新聞

醫(yī)院內(nèi)窺鏡儀器故障的應(yīng)急方法

來源:http://tukouzhao.cn/ 發(fā)布時間:2020-05-23 瀏覽量:0

醫(yī)療用內(nèi)窺鏡設(shè)備定期保養(yǎng)一般由儀管員配合工程技術(shù)人員完成,它是一項(xiàng)不斷循環(huán)進(jìn)行的有組織有計劃的維修措施,有利于出現(xiàn)故障后的查找,定期保養(yǎng)的內(nèi)容和時間,一般可以分3個等級。
The regular maintenance of medical endoscope equipment is generally completed by the instrument administrator in cooperation with the engineering and technical personnel. It is an organized and planned maintenance measure that is constantly circulating, which is conducive to the search after failure. The content and time of regular maintenance can be generally divided into three levels.
(1)一保:一般可以一個月一個季度進(jìn)行一次.主要內(nèi)容除廠日常維護(hù)的工作外,可以拆開機(jī)殼,各處積塵,污垢、異物、緊固螺絲、添加潤滑劑;檢查務(wù)器件、元件有無磨損、變形、燒蝕、擊穿、松動,受潮,老化、接地不良等情況;檢測各組電源電壓及紋波,檢查高壓部件運(yùn)行和接觸情況等。
(1) First warranty: generally, it can be carried out once a month to a quarter. In addition to the daily maintenance work of the plant, the main content is to dismantle the casing, remove dust, dirt, foreign matters, tighten screws and add lubricants everywhere; check whether the service components and elements are worn, deformed, ablated, broken, loose, damped, aged, poorly grounded, etc; Check the power supply voltage and ripple of each group, and check the operation and contact of high-voltage components.
(2)二保:一般可以半年一年進(jìn)行一次。主要內(nèi)容除做好一保外,可以對整機(jī)控制臺上的各個儀表及操作控制系統(tǒng)的靈敏度,精度進(jìn)行測試校正和計量檢定,更換高壓發(fā)生器絕緣汕等到期的損耗品,對電路中各測試點(diǎn)的電壓,波形進(jìn)行系統(tǒng)檢測和做拉偏試驗(yàn)。
(2) Second guarantee: generally, it can be carried out once every six months to one year. In addition to the first guarantee, it can test, calibrate and measure the sensitivity and accuracy of each instrument and operation control system on the console of the whole machine, replace the expired loss products such as the insulation of the high-voltage generator, and systematically test the voltage and waveform of each test point in the circuit and conduct pull deflection test.
(3)三保:一般可以2-4年進(jìn)行一次:主要內(nèi)容除做好二保外,必要寸可以將整機(jī)進(jìn)行全部拆卸子以清洗檢修,超過使用期的元器件應(yīng)盡量更換或修復(fù),應(yīng)對儀器進(jìn)行較為徹底的調(diào)試,恢復(fù)其工作精度和性能,達(dá)到或超過新機(jī)的程度是完全有可能的。
(3) Three Guarantees: generally once every 2-4 years: in addition to the two guarantees, the whole machine can be disassembled for cleaning and maintenance if necessary. The components beyond the service life shall be replaced or repaired as much as possible. The instrument shall be fully and thoroughly debugged to restore its working accuracy and performance, and it is completely possible to reach or exceed the level of the new machine.
內(nèi)窺鏡設(shè)備維修
醫(yī)療用內(nèi)窺鏡設(shè)備保養(yǎng)
Medical endoscope equipment maintenance
在醫(yī)院各科室中,醫(yī)療用內(nèi)窺鏡的使用極其嚴(yán)格,內(nèi)窺鏡對使用環(huán)境的要求:室內(nèi)環(huán)境以暗室環(huán)境為主,避免強(qiáng)光直射,手術(shù)開始關(guān)閉日光燈,用無影燈照明,術(shù)前室內(nèi)的溫度保持在22℃~25℃、濕度50%左右、防酸、防堿、防蒸氣。避免強(qiáng)電、電磁場的干擾。手術(shù)中確保電壓穩(wěn)定,連續(xù)穩(wěn)壓器維持電壓220V以免損壞精密儀器。
In all departments of the hospital, the use of medical endoscopes is extremely strict. The requirements for the use environment of endoscopes are as follows: the indoor environment is mainly dark room environment, avoiding direct light, the operation starts to turn off the fluorescent lamp, lighting with shadowless lamp, the indoor temperature before the operation is kept at 22 ℃ ~ 25 ℃, the humidity is about 50%, acid proof, alkali proof and steam proof. Avoid the interference of strong electricity and electromagnetic field. During the operation, the voltage is stable, and the continuous voltage regulator maintains the voltage of 220V to avoid damaging the precision instrument.
醫(yī)用內(nèi)窺鏡在不同的時期都促進(jìn)了醫(yī)學(xué)事業(yè)的不斷發(fā)展。今后隨著電子技術(shù)及其他科學(xué)技術(shù)的不斷進(jìn)步,相信其技術(shù)會有更廣更深的發(fā)展。
Medical endoscopy has promoted the continuous development of medical cause in different periods. In the future, with the continuous progress of electronic technology and other science and technology, I believe that its technology will have a broader and deeper development.
醫(yī)用內(nèi)窺鏡技術(shù)發(fā)展到今天,已經(jīng)顯示出它的強(qiáng)大生命力,相信明天會做出更輝煌的貢獻(xiàn)。
With the development of medical endoscopy technology, it has shown its strong vitality. I believe that it will make more brilliant contributions tomorrow.
關(guān)于醫(yī)院內(nèi)窺鏡故障診斷http://tukouzhao.cn/就先介紹到這里了,本文由內(nèi)窺鏡設(shè)備維修友情奉獻(xiàn),相信大家在實(shí)際的工作中會用到相關(guān)知識,如果想要了解更多,可以關(guān)注一下濟(jì)南匠仁醫(yī)療設(shè)備有限公司。
Composition and diagnosis of endoscopy in hospital http://tukouzhao.cn/ This article is dedicated to the maintenance of endoscope equipment. I believe that you will use relevant knowledge in actual work. If you want to know more, you can pay attention to Jinan Jiangren Medical Equipment Co., Ltd.
s
新聞資訊
聯(lián)系我們
  • 公司公司:匠仁醫(yī)療設(shè)備有限公司
  • 匠仁醫(yī)療山東濟(jì)南維修部
  • 聯(lián)系人:樊經(jīng)理
  • 電話:13153199508
  • 地址:山東省濟(jì)南市槐蔭區(qū)美里東路3000號德邁國際信息產(chǎn)業(yè)園6號樓101-2室
  • 匠仁醫(yī)療湖南長沙維修部
  • 聯(lián)系人:李經(jīng)理
  • 電話:13873135765
  • 地址:湖南省長沙市雨花區(qū)勞動?xùn)|路820號恒大綠洲14棟2409室
新聞資訊

樊經(jīng)理:13153199508     李經(jīng)理:13873135765

公司地址:山東省濟(jì)南市槐蔭區(qū)美里東路3000號德邁國際信息產(chǎn)業(yè)園6號樓101-2室  湖南省長沙市雨花區(qū)勞動?xùn)|路820號恒大綠洲14棟2409室

     

魯公網(wǎng)安備 37010402441281號